Running an SDS-PAGE Gel:
Note that the following uses pre-cast gels and pre-made running buffer, see accessory protocols [NotDoneYetDudez] for casting gels and making your own running & loading buffers
Supplies:
- ~1L of 1x Invitrogen MES PAGE Running Buffer (supplied at 20x, Life Tech. Cat. No. XXXX)
- 1 or 2 precast acrylamide gels (I like the 4-20% gradient gels, e.g. Life Tech Cat. No. XXXX)
- 4x SDS-PAGE Running Buffer (Life Tech Cat. No.)
- Gel Running Chamber (Life Tech Cat. No. XXXX)
- DC Power Supply
- Prestained Protein Ladder (e.g. Pierce PageRuler Plus, Pierce Cat. No. XXXX)
- SimplyBlue SafeStain Coomassie staining solution (Life Tech Cat. No. XXXX)
- Thermocycler or 95degC Heat Block
Preparing the Samples:
- For protein solutions (e.g. column flow-through, cleared lysate, purified protein):
- Add 1/3 vol. 4x SDS-PAGE Sample Loading Buffer and pipette up and down to mix
- Incubate sample at 95degC 5min
- I like to do this step in the thermocycler; prepare < 50uL of sample + loading buffer in a 0.2mL PCR tube or strip and incubate at least 5min @ 95C
- For E. Coli cultures (e.g. to check protein expression):
- Remove a small amount of culture (25uL is good) DON'T spin down
- Add 1 vol. of 4x sample buffer directly to the culture
- Incubate 5min @ 95degC in the thermocycler
- Dense cultures can become viscous and nearly impossible to load after boiling; if this is the case, repeat above steps with 1-3 more volumes of sample buffer, or dilute culture 2-4x with water
- spin tubes briefly to remove condensation from cap
- Note that you don't need to boil the pre-stained ladder
Setting up the Gel Rig, Loading, and Running:
- Prepare 1x running buffer (50mL of 20x in 1L ddH2O is usually enough for mini gels)
- Open gel packages
- MAKE SURE TO REMOVE TAPE STRIP FROM BOTTOM OF GEL OR IT WON'T RUN
- If running 2 gels, put one on either side of the white electrode assembly, with the short plate facing inwards (gels should be 'facing' one another)
- If only running one gel, use the plastic buffer dam in place of the 2nd gel (writing faces inwards)
- Remove plastic combs from the tops of the gels
- Pour running buffer into top chamber (between gels) until buffer level is higher than the top of the (shorter) inner gel plate (i.e. until buffer covers the wells). Leave for a minute or two to make sure there are no leaks (buffer level doesn't drop).
- Fill the outer chamber until ~3/4 of the gel is covered.
- [Optional, but recommended] Use a 1mL pipet to wash some running buffer into wells to clear out any gel fragments or unpolymerized acrylamide
- Load samples into wells with a P20 tip or gel-loading tip
- 5uL is usually sufficient for a 1mm gel; I wouldn't load more than 10uL unless you know you have a very dilute sample
- Load 2-5uL of Prestained Ladder
- Attach lid and run gel!
- 1hr at 150V is usually sufficient
- If running for a western blot, run until dye front has passed completely out of the gel
Staining (with SimplyBlue Coomassie):
- Remove gels & break open plastic cassette by using a metal scoopula to pry apart the plates along the edges
- carefully remove top (short) plate
- lift from bottom of gel to prevent gel sticking to plate
- use a razor to cut along edges of the gel and remove the comb
- cut by pushing directly down into the gel; if you run the razor horizontally along the edge the gel will tear
- If staining multiple gels, cut off a corner to tell them apart
- CAREFULLY lift the gel out of the cassette (very easy to tear, esp. 1mm gels!). Transfer to a tupperware container or pipet tip box lid
- Can stain 2 gels in one container
- Repeat 3x:
- Add 100mL of ddH2O, and microwave one minute at full power
- Gently shake on an orbital shaker (~60RPM) for 1min
- Pour off water into sink
- hold onto corner of gel, easy to lose it down the drain
- Add 25mL of SimplyBlue Coomassie stain to the gel(s) and microwave until stain just starts to boil (usually < 30s)
- use 35mL for thick gels or to do two thin gels at once
- Cover and gently shake (<60rpm) at RT for 5 minutes
- Pour off stain (can dump down drain) and add 100mL diH2O
- Shake 10min at RT
- [OPTIONAL (though I almost always do it)]:
- Pour off H2O and add same volume of 20% NaCl, then shake 5min RT
- Gel will be stable in this solution at 4C for a few days at least
- Image gel on the WEL gel doc using the COOMASSIE BLUE protocol with the white-light screen in place.
- Gels can be disposed of in regular trash
Barrick Lab > ProtocolList > ProtocolsRunningSDSPAGEProteinGels
Contributors to this topic
ColinBrown
Topic revision: r1 - 2016-06-28 - 15:46:11 - Main.ColinBrown